Project Grade 9 Science

The Aldwinter High Water Audit: Finding the Standing Leak

A four-session grade 9 project where students meter their school's overnight water use, test one low-cost fix, and propose retrofits to a fictional facilities director.

Objectives

  1. Students will measure a building's overnight standing water use from meter readings.
  2. Students will measure fixture flow rates and identify the largest contributors to standing use.
  3. Students will test one change and report the measured effect in a written proposal.

Vocabulary

Flow rate
Flow rate measures how much water moves past a point in a certain amount of time, like gallons per minute through a garden hose. Bigger pipes and stronger pushes give bigger flow rates.

Also: standing use, aerator, flapper valve, baseline, retrofit

Teacher overview

Utilities find hidden leaks by watching what a meter does when nobody is using water, and a school building offers the same opportunity every night. Over four sessions, student teams read their school's water meter to establish an overnight baseline, inventory and time the fixtures, test one low-cost change, and then measure the same overnight window again. The driving question is whether the building is losing water while it is empty, and what it would cost to stop it. The deliverable is a written proposal with a data appendix, addressed to a fictional facilities director who has a small budget and no patience for estimates that are not measured.

Rubric

Criterion Emerging Developing Proficient Advanced
Measurement quality Readings are missing, undated, or taken inconsistently Most readings are present but the overnight windows differ in length without adjustment Readings are complete, timed consistently, and converted correctly to gallons per hour Readings are complete and consistent, and the team notes and accounts for events that could distort a window
Testing the variable More than one thing changed, or the change is not documented One change made but the change log is incomplete Exactly one change made, fully logged, with before and after measured the same way One change made and logged, measured identically before and after, with a stated reason the comparison is fair
Use of evidence in the proposal Recommendation is not supported by team data Recommendation cites data but interprets it loosely Every claim traces to a recorded measurement, and the results table and graph match the text Claims trace to measurements, and the proposal states how confident the team is and why
Meeting the constraints Proposal exceeds the budget or requires a licensed plumber Meets some constraints, ignores others Meets all four constraints and shows the parts total Meets all four constraints, shows the total, and explains what the team would cut first if the budget were smaller
Communication to the client Disorganized; the recommendation is hard to find Recommendation present but buried in detail Clear summary page, readable table and graph, appropriate tone for a district director Summary page stands alone, visuals are labeled and self-explaining, and the presentation answers questions directly

Differentiation

Support

Assign these students the fixture inventory and the timing work, which is concrete and produces immediate data, and give them a partly completed data sheet with the columns labeled and the first row filled in. Provide a conversion card showing how to turn seconds per gallon into gallons per minute. Reduce the written proposal to the summary page and the results page, with the appendix collected as raw sheets.

Extension

Ask these students to estimate the annual cost of the standing use they measured, using the school district's actual water rate if the business office will share it, and to calculate a simple payback period for the parts they recommend. They can also design a second test that would separate leaking toilets from dripping faucets more cleanly than the first one did.

ELL supports

Pre-teach "meter," "reading," "standing use," "flapper valve," and "aerator" at the fixtures themselves during Session 1, pointing to each part. Provide a bilingual data sheet with picture labels for each fixture type, and give the proposal a paragraph-by-paragraph outline with sentence frames such as "Our team measured ___ gallons per hour overnight before the change and ___ gallons per hour after."

Extensions

Invite the fictional client's real counterpart, the district facilities director or a custodian, to hear the presentations and respond to the recommendations. Teams that measured a clear reduction can prepare a one-page summary for the school newsletter that explains what was changed and what the meter showed, using their own graph rather than a stock image.