Worksheet Grade 9 Science

Dunmore Lead Tap Sampling: Reading the Action Level

A grade 9 worksheet where students analyze a fictional town's lead tap-sampling data, find the 90th-percentile value, and compare it to the action levels.

Objectives

  1. Students will find the 90th-percentile value of a small lead-sampling data set.
  2. Students will compare sample results against the current and future federal action levels.
  3. Students will explain how corrosion control and sampling method affect lead readings.

Vocabulary

Action level
A trigger number in lead and copper testing. If too many homes test above this level, the utility must take steps like improving treatment and telling the public.
Corrosion control
Treatment that keeps water from slowly eating away at the inside of pipes. It helps stop metals like lead from getting into drinking water.
First-draw sample
A water sample taken from a faucet after the water has sat still in the pipes for hours, usually first thing in the morning. It shows how much lead can build up in water that sits in a home's pipes.

Also: 90th percentile

Teacher overview

Utilities check for lead by collecting first-draw tap samples from homes that are likely to have lead pipes or lead solder. A system does not pass or fail on a single house. Instead, the rule looks at the 90th-percentile value across the samples and compares it to the action level, which is 15 parts per billion now and drops to 10 parts per billion in 2027. EPA's health-based goal for lead in drinking water is zero, so the action level is a trigger for treatment and public notice rather than a safe level. This worksheet has students work with a small sampling data set from the fictional town of Dunmore.

A common student error is to compare only the highest sample to the action level. The rule uses the 90th percentile, not the single worst house, so students should sort the data and find that value carefully.

Answer Key

  1. Answer: 19 ppb. 22 − 3 = 19 parts per billion.
  2. Answer: 2 samples. Only 16 and 22 are above 15 parts per billion.
  3. Answer: 20 percent. 2 of 10 samples exceed the level, and 2 ÷ 10 × 100 = 20 percent.
  4. Answer: 16 ppb. Sorted in order, the 9th of the 10 values is 16 parts per billion.
  5. Answer: 1 ppb. 16 − 15 = 1 part per billion above the action level.
  6. Answer: 4 samples. The values 11, 13, 16, and 22 are all above 10 parts per billion.
  7. Answer: 40 percent. 4 of 10 samples exceed 10 parts per billion, and 4 ÷ 10 × 100 = 40 percent.
  8. Answer: Because water sitting in a lead pipe overnight has more time in contact with the metal, so more lead dissolves into it. Water that has run for two minutes has cleared most of that standing water out of the pipe.
  9. Answer: The corrosion-control chemical builds a thin protective coating on the inside of the pipe. That coating keeps the water from touching the lead directly, so less lead dissolves into the water even though the lead pipe is still there.
  10. Answer: No. The lab reports to the nearest whole part per billion, so the extra decimal in 16.0 claims more precision than the measurement supports. The student should write 16 parts per billion.

Differentiation

Support

Provide the data already sorted from lowest to highest, and mark the 9th value so students can focus on the interpretation in items 4 and 5 rather than the sorting step.

Extension

Have students change one of the 10 results so that the 90th-percentile value (the 9th value in order) would fall below the 15 parts-per-billion action level, and explain why the value they chose changes the result.

ELL supports

Pre-teach "action level," "first-draw sample," and "corrosion control" with a labeled pipe diagram showing standing water and a protective coating. Allow items 8 and 9 to be answered with a labeled sketch and a short phrase.