Lab / experiment Grade 12 Engineering & Design

Bench-Testing a Small Pump: Building a Head-Capacity Curve

A grade 12 lab where students measure a small pump's flow at increasing discharge heights, plot the head-capacity curve, and estimate shutoff head from the graph.

Objectives

  1. Students will measure a pump's flow rate at several discharge heights and compute flow in liters per minute.
  2. Students will plot a head-capacity curve and interpret its decreasing shape and intercepts.
  3. Students will estimate shutoff head from their curve and connect lift to pressure in a full-scale system.

Vocabulary

Key words: head, capacity, shutoff head, discharge, head-capacity curve

Teacher overview

A centrifugal pump delivers less water as the height it must lift that water increases, and the graph of that relationship, with head on one axis and flow on the other, is what an engineer consults when selecting a pump for a given service. Manufacturers publish these head-capacity curves for full-scale equipment, and a small aquarium pump produces its own version on a benchtop. In this lab, students time how long their pump takes to deliver one liter at a series of discharge heights, build the curve from their own data, and push the discharge up until flow stops entirely at the pump's shutoff head.

Answer Key

  1. Answer: varies by group's own data. Flow = 60 ÷ average seconds per liter. A pump that averaged 15 seconds, for example, delivered 60 ÷ 15 = 4.0 liters per minute.
  2. Answer: flow decreases as lift increases. Accept any description consistent with the group's plot; most small pumps show flow falling as the outlet rises, dropping toward zero increasingly steeply near shutoff.
  3. Answer: 5.0 liters per minute. Flow = 60 ÷ 12 seconds = 5.0 liters per minute at the 30-centimeter lift.
  4. Answer: 60 percent decrease. Flow at 90 centimeters = 60 ÷ 30 = 2.0 liters per minute. The decrease is (5.0 − 2.0) ÷ 5.0 = 0.60, or 60 percent.
  5. Answer: varies by group's own data. The estimate is where the smooth curve crosses zero flow, and it should sit near the Step 6 measurement. The intercept matters because shutoff head is defined as the lift at which the pump can no longer move any water.
  6. Answer: 40 psi. 92.4 feet ÷ 2.31 feet per psi = 40 psi of pressure just to reach the tank's water surface, before friction losses are added.

Differentiation

Support

Reduce the run to three heights (20, 60, and 100 centimeters) with the data table pre-labeled, and provide the flow formula worked once with a sample time so groups only repeat the pattern. Assign the timing role to a student comfortable with the stopwatch and rotate after each height.

Extension

Have groups tape two identical pumps' outlets into a single tee fitting, if a second pump is available, and test whether two pumps in parallel move more water at the same 60-centimeter lift than one pump alone, connecting the result to why utilities run pump stations with multiple units.

ELL supports

Label a photo or sketch of the setup with "pump," "outlet," "lift height," and "water surface" before starting, and post the roles (holder, timer, recorder) as picture cards. Provide a sentence frame for question 2: "When the lift gets higher, the flow gets ___."